Least Cost Routing
LCR CO Line Programming Reference Table
Program 50-1 – LCR Parameters
Processor Type:
Program Type:
Initialized Default:
LED
On
01
02
03
04
05
10
Program 50-1 Overview
This program defines general operating parameters for LCR software.
Program 40 denies CO line access via LCR, but denies all other access methods.
G
Program 41 allows CO line access via LCR, but denies all other outgoing access methods:
G
(#7001~#7200, 801~816, Line button).
Toll Restricted standard telephones should be forced to dial outgoing calls via LCR. This is to
G
prevent Toll Restriction defeat when the QRCU3, K4RCU3, K5RCU or RRCS times out.
LED 01: Enable System LCR
LED 01 On: LCR software is enabled system-wide. For the Hospitality Management Information
System (HMIS), this LED must always be set to On.
LED 01 Off: LCR software is disabled. None of the LCR programming referred to by this section
is recognized. Dial 9 access assigned in Program 16 is enabled.
LED 02: Not used
LED 03: 555 LDI Route Per Program 50-4
LED 03 On: LCR routes long distance information (LDI) calls over the plan number specified in
Program 50-4.
LED 03 Off: LCR routes LDI calls using area codes specified in route plans in the following table,
as it would for any other call.
5-4
DK14, DK40i, all RCTUs and BCUs
Least Cost Routing
All LEDs Off
SELECT = 1
Enable System LCR
Not Used
555 LDI Route per Program 50-4
Dial Tone After LCR Access
Warning Tone Last Choice Route Number
No CO Dial Tone After Line Access
Route Plans
Processor
Supported
DK14
8
DK40i
8
RCTUA
8
Press LED Buttons for each LCR parameter
Off
No LCR
Not Used
Per Area Code Table
Silent
No Warning Tone
CO Dial Tone (R4.15)
Route Plans
Processor
Supported
RCTUBA/BB
RCTUC/D
RCTUE/F
8
16
16
Strata DK Programming 5/00