3- Wall Mount the XN120 system
Installation Considerations:
·
To avoid electric shock or damage do not plug in or turn on the system power before completing the
installation.
·
Avoid working with the system during electrical storms.
·
Use the power cord supplied with the product.
·
Do not bundle power cords together, the cords may overheat.
·
Ensure the system has a suitable Earth Ground connection.
Environmental Considerations – Be sure the system is not:
·
In direct sunlight or in hot, cold or humid places.
·
In dusty areas or in areas where sulfuric gasses are produced.
·
In places where shocks or vibrations are frequent or strong.
·
In places where water or other fluids may come into contact with the equipment.
·
In areas near electric welders or machines that emit high frequency radiation.
·
Near computers, microwaves, air conditioners etc.
·
Near radio antennas (including shortwave).
·
If you are installing the optional expansion box or expansion cabinets ensure there is sufficient wall
space and ventilation. Refer to the wall mounting diagrams below.
1
You will need a minimum of
560mm x 680mm (W x H) wall
space for the XN120 system.
The system is 360mm x
279mm (W x H)
! You will need more space if
you are installing the optional
units:
·
2OPBox
·
Expansion cabinets
Refer to the installation
instructions supplied with
these units.
XN120 Getting Started Guide
Use the wall mount template supplied to mark the four screw locations.
Ensure that you use the correct wall plugs for the type of wall.
Leave approximately 3~5mm of the screw
protruding from the wall.
Have 100mm on
the left side of
the system for
the power cable.
Wall Mount the XN120 System
Have 200 mm above
the system for
ventilation.
Have 200mm below the system
for other cables connected to the
system.
Have 100mm
on the right
side.
! additional
146mm if you
have a
2OPBOX