RM-495; RM-496
RF troubleshooting
ST_CDSP_GSM_TX_POWER_TEST is fatal
This test is checking power amplifier functionality.
Error code
ST_GSM1800_TX_PWR_LOW
(0x00, 0x02)
ST_GSM850_TX_PWR_LOW
(0x00, 0x08)
Or combination (0x00, 0x0A)
ST_TXDAC_FAIL (0x00, 0x10)
Or combination (0x00, 0x1A),
(0x00, 0x12), (0x00, 0x18)
ST_CDSP_TX_PLL_PHASE_LOCK_TEST is fatal
This test is checking if phase lock loop is working.
Error code
ST_TX_PLL_FAIL (0x00, 0x08)
ST_CDSP_RX_IQ_LOOP_BACK_TEST is fatal
This test is checking the analogue RX communication between baseband and RF.
Error code
ST_FIMRCAL_FAIL (0x00, 0x40)
or combination (0x00, 0x50)
and (0x00, 0x60)
Issue 1
-
-
COMPANY CONFIDENTIAL
Copyright © 2008 Nokia. All rights reserved.
Test
Test
Test
Action
Replace N1002
Replace N1001
Action
Replace N1001
Action
Replace N1001
Page 4 –13