RM-376
System Module and User Interface
Figure 21 Internal earpiece circuitry
Internal speaker
The output power for the auxiliary speaker output is typically 0.6 W sine wave into impedance is 7 ohm in 1k
Hz. The 2608 also supports a hands-free speaker.
Figure 22 Internal speaker circuitry
V
ibra circuitry
Vibra is used for Vibra alarm function
.
The vibra motor is connected to QSC6020 via VIB_DRV_N.
Vibra is built into cover and connected via cable to plug on PWB.
Figure 23 Vibra circuitry
Page 5-28
Company Confidential
Issue1
Copyright © 2008 Nokia. All rights reserved.