Air-conditioner Control System Optional Parts
Mounting attachment A type for use with AG-150A
PAC-YG85KTB
Installation Manual
1 Safety Precautions
• Before installing the Mounting attachment A type, please read the following safety precautions carefully to ensure proper
installation.
• Observe the following precautions to ensure safety.
• The following symbols are used in this manual to indicate the type and severity of potential consequences that may result when
given instructions are not followed exactly as stated.
WARNING
Indicates a risk of death or serious injury.
CAUTION
Indicates a risk of injury or damage to the product.
• After the completion of installation, perform a test run to confirm proper operation.
• Retain this manual for future reference. When the unit is reinstalled or repaired, make this manual available to those who provide
these services. Make sure that the manual is passed on to any future air condition system users.
Only a dealer or qualified technician should replace
the unit.
Improper replacement by an unqualified person may result
in electric shock or fire.
The Mounting attachment A type should be installed
on a surface that is strong enough to support the
weight of the unit.
If the Mounting attachment A type is installed on a surface
that lacks the strength to support it, it may fall and cause
injury.
Do not attempt to modify or repair the Mounting
attachment A type.
Modification or improper repair may result in electric shock
or fire. Consult your dealer when repairs are necessary.
Do not install the Mounting attachment A type where
there is a risk of leaking flammable gas.
If the leaked gas accumulates around the Mounting
attachment A type, it may ignite and cause an explosion.
Do not use the Mounting attachment A type in an
environment that has high concentrations of oil,
steam, or sulfuric gas.
These substances may have adverse effects on the
performance of the Mounting attachment A type or
damage its parts.
Seal the wire access holes with putty to prevent dew,
water, and insects from entering to avoid electric
shock.
WARNING
Install the Mounting attachment A type properly
according to the instructions detailed in this
Installation Manual.
Improper installation by an unqualified person may result in
electric shock or fire.
Electric work must be performed by authorized
personnel according to the local regulations and the
instructions detailed in the Installation Manual.
Inadequate circuit capacity or improper installation may
result in electric shock or fire.
Ask your dealer or an authorized technician to move
the Mounting attachment A type.
Improper installation by an unqualified person may result in
electric shock or fire. Consult your dealer or a qualified
technician.
CAUTION
Do not install this Mounting attachment A type in a
place that has the potential for steam, such as a
bathroom or kitchen.
Steam may cause an electric shock or a unit malfunction.
Do not install this Mounting attachment A type where
an acid, alkaline solution, or special chemical spray is
used frequently to avoid electric shock or malfunction.
Keep the cables from coming in direct contact with the
edges of the wire access holes.
If the cables are damaged, they may cause electric shock
or fire.
This Mounting attachment A type is for exclusive use
with the AG-150A and cannot be used with other
devices.
- 1 -
Applicable
Centralized Controller
AG-150A
Model

Advertisement

loading

Summary of Contents for Mitsubishi Electric AG-150A

  • Page 1 Seal the wire access holes with putty to prevent dew, or fire. water, and insects from entering to avoid electric This Mounting attachment A type is for exclusive use shock. with the AG-150A and cannot be used with other devices. - 1 -...
  • Page 2: Parts List

    Quantity Use screws that are suitable for the wall type. The weight of the AG-150A including the Mounting attachment A type (PAC-YG85KTB) and power supply unit (PAC-SC51KUA) is 5.1 kg (12 lbs). (The weight of the Mounting attachment A type is 1.7 kg (4 lbs.) by itself.) Use screws with the head size of between 8 and 11.8 mm (3/8 and 1/2 in).
  • Page 3: External Dimensions

    4 External Dimensions 100.6(4) 299(11- 75(3) 250(9- Wall mounting screw hole (6) Under the cover ø 1 / 4 5.5 ( 1 / 2 12 ( 220(8- >PC+ABS< Unit: mm (in) - 3 -...
  • Page 4: Selecting An Installation Site

    5 Selecting an Installation Site 1. Required installation space Install the Mounting attachment A type (PAC-YG85KTB) where the space indicated in the figure below can be secured. Mounting attachment A type (PAC-YG85KTB) 30 (1- 13 /16 299 (11- 151 (6) 30 (1- 3 /4 399(15-...
  • Page 5 (2) Cut out the knockout hole on the Mounting attachment A type (PAC-YG85KTB) at the top with a nipper for the cable (the thin part of the plastic). >PC+ABS< NOTE Install the Mounting attachment A type (PAC-YG85KTB) so that the arrow ( UP) on the back of it points up. (3) Sand the cut surface of the knockout hole smooth.
  • Page 6 M4 screws (supplied with PAC-YG85KTB) (7) Connect the cables to the power supply unit (PAC-SC51KUA). Refer to the PAC-SC51KUA Installation Manual for details. (8) Remove AG-150A surface cover. Insert a flat-tip screwdriver in the holes indicated and move the handle up to remove the cover.
  • Page 7 (9) Connect the wiring from the power supply unit to the centralized controller. Back of AG-150A DC power cable M-NET transmission cable DC power cable (Supplied) M-NET transmission cable (Supplied) DC power line and M-NET transmission cable are connected using a connector as shown figure below. Connectable to the connector using the cable that is supplied.
  • Page 8 (10) If the AG-150A is not always connected to the LAN, connect the supplied LAN link-up cable to the LAN connector. (* If the AG-150A is always connected to the LAN, connect the LAN cable (field supplied) via a HUB and the LAN link-up cable is not required.)
  • Page 9 If the LAN link-up cable is used, place it inside the Mounting attachment A type as shown in the figure below. LAN link-up cable (14) Attach the cover on the AG-150A. (15) Attach the power supply unit cover with the two screws.
  • Page 10 2. To route the cable from the bottom (1) Remove the cover of Mounting attachment A type. (Refer to section 1.(1).) (2) Cut out the knockout hole on the Mounting attachment A type (PAC-YG85KTB) at the bottom with a nipper for the cable. NOTE Install the Mounting attachment A type (PAC-YG85KTB) so that the arrow ( UP) on the back of it points up.
  • Page 11 The LAN link-up cable is used for maintenance purpose when the AG-150A is not always connected to the LAN. If the AG-150A is not always connected to the LAN, connect a LAN cable to the LAN link-up cable to upgrade the AG-150A software as necessary.
  • Page 12 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG. , 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. WT05423X01...