Page 5
Installation and Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. This section describes the steps required to set up your system for the first time. Unpack the System Unpack your system and identify each item. Installing the Rails and System in a Rack Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided...
Page 6
Installing the Blades Beginning at the top, slide the modules into the enclosure from left to right. When the blade is securely installed, the handle returns to the closed position. Connecting the CMC and KVM Modules Connect the serial cable and network cable(s) from the management system to the CMC module.
Page 7
Connecting the System to Power Connect the system’s power cables to the system power supplies. CAUTION: To prevent the power cables from being disconnected accidentally, use the plastic clip on each power supply to secure the power cable to the power supply, and use the Velcro strap to secure the cable to the strain-relief bar.
Page 8
Turning On the System Press the power button on the enclosure. The power indicator should light. NOTE: Once you have connected the system to the power supplies, there may be a minimal delay before you can turn on your system. Turning On the Blades Press the power button on each blade, or power on the blades using the systems management software.
Page 9
Complete the Operating System Setup If you purchased a preinstalled operating system, see the operating system documentation that ships with your system. To install an operating system for the first time, see the installation and configuration documentation for your operating system. Be sure the operating system is installed before installing hardware or software not purchased with the system.
Page 10
Operating System M915 M910 M905 M805 M710 M710HD M610 M610x M605 Microsoft Windows Server 2008 Standard and Enterprise (x86) Editions with SP2 Microsoft Windows Server 2008 Standard, Enterprise, and Datacenter (x64) Editions Microsoft Windows Web Server 2008 (x64) Edition Microsoft Windows Web Server 2008 (x64) Edition with SP2...
Page 11
Operating System M915 M910 M905 M805 M710 M710HD M610 M610x M605 Microsoft Windows Server 2003 Standard and Enterprise (x64) Editions Microsoft Windows Server 2003 R2 Standard and Enterprise (x64) Editions Microsoft Windows Server 2003 R2 Datacenter (x64) Edition Microsoft Windows Server 2003 R2 Standard, Enterprise, and Datacenter...
Page 12
Operating System M915 M910 M905 M805 M710 M710HD M610 M610x M605 Red Hat Enterprise Linux AS and ES (version 4.8) (x86_64) Red Hat Enterprise Linux (version 5.0) (x86) Red Hat Enterprise Linux (version 5.0) (x86_64) Red Hat Enterprise Linux (version 5.2) (x86) Red Hat Enterprise Linux (version 5.5)
Page 13
Dell systems management application documentation provides information about installing and using the systems management software. NOTE: Always check for updates on support.dell.com/manuals and read the updates first because they often supersede information in other documents. Getting Started With Your System...
Page 14
Obtaining Technical Assistance If you do not understand a procedure in this guide or if the system does not perform as expected, see your Hardware Owner’s Manual. Dell offers comprehensive hardware training and certification. See dell.com/training for more information. This service may not be offered in all locations.
Page 15
Technical Specifications Blade Specifications Processor Processor type PowerEdge M915 Two or four AMD Opteron 6000 series processors (eight- or twelve-core processors) PowerEdge M910 Two or four Intel Xeon 7000 series processors (up to eight-core processors) PowerEdge M905 Four dual- or quad-core AMD Opteron 8000 series processors PowerEdge M805 Two dual- or quad-core AMD Opteron 2000 series...
Page 16
Memory (continued) PowerEdge M710, 800, 1066, or 1333 MHz DDR3 single- or dual-ranked M610x, M610, registered DIMMs (RDIMMs) or unbuffered DIMMs (UDIMMs) 800 or 1066 MHz DDR3 quad-ranked registered DIMMs (RDIMMs) or unbuffered DIMMs (UDIMMs) PowerEdge M600 FBD memory modules, rated for 677 MHz operation Memory module sockets PowerEdge M915, M910 32 240-pin sockets...
Page 18
Drives (continued) PowerEdge M600, One 2.5-inch SATA hard drive support through non- M610x, M610 RAID, value RAID, or performance RAID storage card. Two 2.5-inch SATA hard drives support through value RAID or performance RAID storage card. One solid-state disk (SSD) hard drive support through non-RAID storage card.
Page 19
Connectors (continued) Internal Internal Secure Digital One optional flash memory card slot (SD) module (PowerEdge with the internal SD module. M915, M910, M905, M805, M710HD, M710, M610x, M610) Internal Secure Digital One optional vFlash memory card slot for (SD) vFlash module use with the iDRAC Enterprise support.
Page 20
Mezzanine Cards (continued) PowerEdge M610x, M610 Up to two PCIe Gen 2 x8 mezzanine card slots, supporting dual-port Gb Ethernet, 10 Gb Ethernet, FC8 or FC4 (M610 only) Fibre Channel, or 4x DDR Infiniband mezzanine cards. PowerEdge M605, M600 Up to two PCIe x8 mezzanine card slots, supporting dual-port Gb Ethernet, 10 Gb Ethernet, FC8 or FC4 Fibre Channel, or 4x DDR Infiniband mezzanine cards.
Page 21
Physical (continued) PowerEdge M910 Height 38.5 cm (15.2 in) Width 5 cm (2 in) Depth 48.6 cm (19.2 in) Weight (maximum 13.1 kg (29 lb) configuration) PowerEdge M905, M805, M710, M610x Height 38.5 cm (15.2 in) Width 5 cm (2 in) Depth 48.6 cm (19.2 in) Weight (maximum...
Page 22
System Enclosure Specifications Physical Height 44.0 cm (17.3 in) Width 44.7 cm (17.6 in) Depth 75.5 cm (29.7 in) Weight (maximum 178.3 kg (392.2 lb) configuration) Weight (empty) 44.6 kg (98.1 lb) Power Supply Module AC/DC power supply (per power supply) Wattage 2360 W and 2700 W Connector...
Page 23
Four cursor control keys, one select key, and an LCD screen Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. The system is not for use in an office environment. Temperature Operating 10 °C to 35 °C (50 °F to 95 °F)
Page 24
Airborne Contaminant Level Class G1 as defined by ISA-S71.04-1985 I/O Module Specifications For information about the I/O modules and pass-through modules supported on your enclosure, see the Dell PowerEdge M1000e Systems Configuration Guide at support.dell.com/manuals. Getting Started With Your System...
Page 31
完成操作系统安装 支持的操作系统 M915 M910 M905 M805 M710 M710HD M610 M610x M605 操作系统 Citrix XenServer 5.5 Citrix XenServer 5.6 Microsoft Windows Server 2008 Hyper-V Server Microsoft Windows Essential Business Server 2008 Standard 版和 Premium 版 Microsoft Windows HPC Server 2008 (x64) Microsoft Windows Server 2008 Standard 版和...
Page 32
操作系统 M915 M910 M905 M805 M710 M710HD M610 M610x M605 Microsoft Windows Server 2008 Standard 版、 Enterprise 版 和 Datacenter (x64) 版 Microsoft Windows Web Server 2008 (x64) 版 Microsoft Windows Web Server 2008 (x64) 版 (含 SP2 ) Microsoft Windows Server 2008 R2 Standard 版、...
Page 33
操作系统 M915 M910 M905 M805 M710 M710HD M610 M610x M605 Microsoft Windows Server 2003 R2 Datacenter (x64) 版 Microsoft Windows Server 2003 R2 Standard 版、 Enterprise 版和 Datacenter (x64) 版 (含 SP2 ) Red Hat Enterprise Linux AS 、 ES 和...
Page 34
操作系统 M915 M910 M905 M805 M710 M710HD M610 M610x M605 Red Hat Enterprise Linux (版本 5.5 ) (x86) Red Hat Enterprise Linux (版本 5.5 ) (x86_64) Red Hat Enterprise Linux (版本 6.0 ) (x86_64) SUSE Linux Enterprise Server 10 (x86_64) SUSE Linux Enterprise Server 10 (x86_64) SP3...
Page 43
系统机壳规格 物理规格 44.0 17.3 44.7 17.6 75.5 29.7 178.3 392.2 44.6 98.1 电源设备模块 功率 2360 W 2700 W 连接器 IEC C20 散热 1205 BTU/ 最大涌入 电流 55 A 14.4 A 200 240 VAC 50/60 Hz 可选的 Avocent iKVM 模块 USB 2.0 ACI 端口...
Page 44
10/100/1000 Mb RJ-45 串行 DTE 16550 视频 CR 2032 3.0 V 机壳控制面板 USB 2.0 视频 功能 环境参数 注: dell.com/environmental_datasheets 运行时 10 C 35 C 50 F 95 F 注: 2955 1 C (1.8 F) 存储时 40 C 65 C 40 F 149 F 运行时...
Page 47
Dell PowerEdge M1000e, M915, M910, M905, M805, M710HD, M710, M610x, M610, M605, dan M600 Memulai Dengan Sistem Anda Model BMX01, Seri HHB, Seri FHB...
Page 49
Instalasi dan Konfigurasi PERINGATAN: Sebelum melakukan prosedur berikut, bacalah petunjuk keselamatan yang disertakan dengan sistem. Bagian ini menguraikan langkah-langkah yang diperlukan untuk mengatur sistem Anda untuk pertama kali. Membuka Kemasan Sistem Buka kemasan sistem Anda dan kenali setiap komponen. Memasang Rel dan Sistem dalam Rak Rakit rel dan pasang sistem dalam rak dengan mengikuti petunjuk keselamatan dan petunjuk pemasangan rak yang diberikan bersama enklosur Anda.
Page 50
Memasang Blade Dimulai dari atas, geser modul ke enklosur dari kiri ke kanan. Ketika blade telah terpasang dengan aman, tangkai kembali ke posisi tertutup. Menghubungkan Modul CMC dan KVM Hubungkan kabel serial dan kabel jaringan dari sistem manajemen ke modul CMC.
Page 51
Menghubungkan Sistem ke Daya Menghubungkan kabel daya sistem ke pencatu daya sistem. PERHATIAN: Untuk mencegah kabel daya terputus secara tidak sengaja, gunakan klip plastik pada setiap pencatu daya untuk mengunci kabel daya ke sumber tenaga listrik, dan gunakan Velcro strap untuk mengunci kabel ke batang pelepas tegangan (strain-relief bar).
Page 52
Menyalakan Sistem Tekan tombol daya pada enklosur. Indikator daya seharusnya menyala. CATATAN: Setelah Anda menghubungkan sistem ke pencatu daya, mungkin ada waktu tunda minimal sebelum Anda dapat menyalakan sistem. Menyalakan Blade Tekan tombol daya pada setiap blade, atau adya pada blade dengan menggunakan perangkat lunak manajemen sistem.
Page 53
Menyelesaikan Pengaturan Sistem Operasi Jika Anda membeli sistem operasi yang telah terinstal, lihat dokumentasi sistem operasi yang dikirimkan dengan sistem Anda. Untuk menginstal sistem operasi untuk pertama kalinya, lihat dokumentasi instalasi dan konfigurasi untuk sistem operasi Anda. Pastikan bahwa sistem operasi telah terinstal sebelum Anda menginstal perangkat keras atau perangkat lunak yang tidak dibeli bersama sistem.
Page 54
Sistem Operasi M915 M910 M905 M805 M710 M710HD M610 M610x M605 Microsoft Windows Server 2008 Edisi Standard dan Enterprise (x86) dengan SP2 Microsoft Windows Server 2008 Edisi Standard, Enterprise, dan Datacenter (x64) Microsoft Windows Web Server 2008 Edisi (x64) Microsoft Windows Web Server 2008 Edisi (x64) dengan SP2...
Page 55
Sistem Operasi M915 M910 M905 M805 M710 M710HD M610 M610x M605 Microsoft Windows Server 2003 Edisi Standard dan Enterprise (x64) Microsoft Windows Server 2003 R2 Edisi Standard dan Enterprise (x64) Microsoft Windows Server 2003 R2 Edisi Datacenter (x64) Microsoft Windows Server 2003 R2 Edisi Standard, Enterprise, dan Datacenter...
Page 56
Sistem Operasi M915 M910 M905 M805 M710 M710HD M610 M610x M605 Red Hat Enterprise Linux (versi 5.0) (x86_64) Red Hat Enterprise Linux (versi 5.2) (x86) Red Hat Enterprise Linux (versi 5.5) (x86) Red Hat Enterprise Linux (versi 5.5) (x86_64) Red Hat Enterprise Linux (versi 6.0) (x86_64) SUSE Linux...
Page 57
• Dokumentasi aplikasi manajemen sistem Dell memberikan informasi mengenai instalasi dan penggunaan perangkat lunak manajemen sistem. CATATAN: Selalu periksa update di situs support.dell.com/manuals dan baca update terlebih dahulu karena biasanya update tersebut menggantikan informasi dalam dokumen. Memulai dengan Sistem Anda...
Page 58
Jika Anda tidak memahami prosedur dalam panduan ini atau jika sistem tidak beroperasi sesuai yang diharapkan, lihat Manual Perangkat Keras untuk Pemilik. Dell menyediakan pelatihan dan sertifikasi perangkat keras secara menyeluruh. Lihat dell.com/training untuk informasi lebih lanjut. Layanan ini mungkin tidak tersedia di semua lokasi.
Page 59
Memori (bersambung) PowerEdge M905, modul memori DDR2, dirancang untuk operasi M805, M605 677 MHz PowerEdge M710HD modul memori DDR3 dan DDR3L single-, dual-, dan quad-rank, yang dirancang untuk 1066 dan 1333 MHz PowerEdge M710, 800, 1066, or 1333 MHz DDR3 single- or dual-ranked M610x, M610, registered DIMMs (RDIMMs) or unbuffered DIMMs (UDIMMs)
Page 60
Memori (bersambung) RAM minimum PowerEdge M915 8 GB PowerEdge M910 4 GB PowerEdge M905 8 GB (Delapan modul memori 1 GB) PowerEdge M805 4 GB (Empat modul memor 1 GB) PowerEdge M710D 4 GB PowerEdge M710, Satu modul memori 1 GB (sistem satu-prosesor) atau M610x, M610 dua modul memori 1 GB (sistem dua-prosesor) PowerEdge M605, M600...
Page 61
Drive Hard Drive PowerEdge M915, M910 Dukungan hingga dua 2.5-inch SAS hard drives melalui kartu penyimpanan RAID nilai atau RAID kinerja . atau Dukungan hingga dua 2.5-inch SSD hard drive melalui kartu penyimpanan RAID nilai atau RAID kinerja . PowerEdge M905, M805 Dukungan hingga dua 2.5-inch SAS hard drives melalui kartu penyimpanan RAID nilai atau RAID kinerja .
Page 62
Drive (bersambung) PowerEdge M605 Dukungan hingga dua 2.5-inch SATA hard drive melalui kartu penyimpanan RAID nilai atau RAID kinerja . atau Dukungan hingga dua solid-state disk (SSD) hard drive melalui kartu penyimpanan non-RAID. atau Dukungan hingga dua 2.5-inch SAS hard drive melalui kartu penyimpanan RAID nilai atau RAID kinerja .
Page 63
Solusi Ekspansi PCIe PowerEdge M610x Mendukung dua single-wide atau satu double-wide full length standard PCIe card. Kartu Mezzanine PowerEdge M915, M910 Hingga empat slot kartu mezzanine PCIe Gen 2 x8, yang mendukung dual-port Gb Ethernet, 10 Gb Ethernet, Kanal Fiber FC8, atau kartu mezzanine Infiniband.
Page 64
Pengontrol Ethernet Yang Tertanam PowerEdge M915, M910, Empat lubang Ethernet dengan dukungan TOE dan M905, M805, M710HD, iSCSI boot, yang disediakan oleh dua pengontrol M710 dual-port Broadcom 5709S Ethernet yang terintegrasi. PowerEdge M610x, M610 Dua lubang Ethernet dengan dukungan TOE dan iSCSI boot, yang disediakan oleh satu pengontrol dual-port Broadcom 5709S Ethernet yang terintegrasi.
Page 65
Fisik (bersambung) PowerEdge M910 Tinggi 38,5 cm (15,2 in) Lebar 5 cm (2 in) Panjang 48,6 cm (19,2 in) Berat (konfigurasi 13,1 kg (29 lb) maksmimum) PowerEdge M905, M805, M710, M610x Tinggi 38,5 cm (15,2 in) Lebar 5 cm (2 in) Panjang 48,6 cm (19,2 in) Berat (konfigurasi...
Page 66
Spesifikasi Enklosur Sistem Fisik Tinggi 44,0 cm (17,3 in) Lebar 44,7 cm (17,6 in) Panjang 75,5 cm (29,7 in) Berat (konfigurasi 178,3 kg (392,2 pon) maksmimum) Berat (kosong) 44,6 kg (98,1 pon) Modul Pencatu Daya Pencatu daya AC/DC (per pencatu daya) Watt Daya 2360 W dan 2700 W Konektor...
Page 67
Empat kunci kontrol kursor, satu kunci pilih, dan sebuah layar LCD Lingkungan CATATAN: Untuk informasi tambahan mengenai pengukuran lingkungan untuk konfigurasi sistem spesifik, lihat dell.com/environmental_datasheets. Sistem tidak untuk digunakan di lingkungan kantor. Suhu Pengoperasian 10 °C hingga 35 °C (50 °F hingga 95 °F)
Page 68
35.000 kaki) Tingkat Pencemaran Udara Kelas G1 sebagaimana didefinisikan oleh ISA-S71.04-1985 Spesifikasi Modul I/O Untuk informasi mengenai modul I/O dan modul pass-through yang didukung pada enklosur Anda, lihat Panduan Konfigurasi Sistem Dell PowerEdge M1000e di support.dell.com/manuals. Memulai dengan Sistem Anda...
Page 75
OS のセットアップの完了 対応 OS M915 M910 M905 M805 M710 M710HD M610 M610x M605 Citrix XenServer 5.5 Citrix XenServer 5.6 Microsoft Windows Server 2008 Hyper- V Server Microsoft Windows Essential Business Server 2008 Standard/Premium Edition Microsoft Windows HPC Server 2008 (x64) Microsoft Windows Server 2008 Standard/Enterprise...
Page 76
M915 M910 M905 M805 M710 M710HD M610 M610x M605 Microsoft Windows Server 2008 Standard/Enterprise (x86)Edition With Microsoft Windows Server 2008 Standard/Enterprise /Datacenter(x64) Edition Microsoft Windows Web Server 2008 (x64)Edition Microsoft Windows Web Server 2008 (x64)Edition With Microsoft Windows Server 2008 R2 Standard/Enterprise /Datacenter(x64)...
Page 77
M915 M910 M905 M805 M710 M710HD M610 M610x M605 Microsoft Windows Server 2003 Standard/Enterprise (x64)Edition Microsoft Windows Server 2003 R2 Standard/Enterprise (x64)Edition Microsoft Windows Server 2003 R2 Datacenter(x64) Edition Microsoft Windows Server 2003 R2 Standard/Enterprise /Datacenter(x64) Edition With SP2 Red Hat Enterprise Linux AS/ES/WS (バージョン...
Page 78
M915 M910 M905 M805 M710 M710HD M610 M610x M605 Red Hat Enterprise Linux(バージョン 5.0) (x86) Red Hat Enterprise Linux(バージョン 5.0) (x86_64) Red Hat Enterprise Linux(バージョン 5.2) (x86) Red Hat Enterprise Linux(バージョン 5.5) (x86) Red Hat Enterprise Linux(バージョン 5.5) (x86_64) Red Hat Enterprise Linux(バージョン...
Page 88
サイズと重量 PowerEdge M915 縦幅 38.5 cm 横幅 5 cm 奥行き 48.6 cm 重量(最大構成) 12.7 kg PowerEdge M910 縦幅 38.5 cm 横幅 5 cm 奥行き 48.6 cm 重量(最大構成) 13.1 kg PowerEdge M905/M805/M710/M610x 縦幅 38.5 cm 横幅 5 cm 奥行き 48.6 cm 重量(最大構成)...
Page 89
バッテリー NVRAM 3.0 V CR 2032 システムエンクロージャの仕様 サイズと重量 44.0 cm 44.7 cm 75.5 cm 178.3 kg 44.6 kg 電源ユニットモジュール AC/DC ワット数 2360 W 2700 W コネクタ IEC C20 熱消費 1205 BTU/ 最大流入 電流 55 A 14.4 A 200 240 VAC 50/60 Hz オプションの...
Page 90
シャーシ管理コントローラモジュール リモート管理 10/100/1000 Mb RJ-45 シリアル 16550 ビデオ 3.0 V CR 2032 エンクロージャのコントロールパネル USB 2.0 ビデオ 機能 環境 メモ: dell.com/environmental_datasheets 動作時 メモ: 900 m 300 m 保管時 –40...
Page 91
350 Hz 0.26 Grms 保管時 250 Hz 1.54 Grms 動作時 41 G 保管時 x y z 71 G 動作時 –15.2 3,048 m 保管時 –15.2 10,600 m クラス G1 ISA-S71.04-1985 I/O モジュールの仕様 お使いのエンクロージャでサポートされている I/O モジュールおよびパ ススルーモジュールについては、support.dell.com/manuals で 『Dell PowerEdge M1000e 設定ガイド』を参照してください。...
Page 93
Dell PowerEdge M1000e, M915, M910, M905, M805, M710HD, M710, M610x, M610, M605 및 M600 시스템 시작 안내서 모델 BMX01, HHB 시리즈 , FHB 시리즈...
Page 94
가에서 Sun Microsystems, Inc.의 상표입니다. 본 발행물에서 특정 회사의 상표 및 회사 이름 또는 제품을 지칭하기 위해 기타 상표 및 상호 를 사용할 수도 있습니다. Dell Inc.는 자사가 소유하고 있는 것 이외에 기타 모든 상표 및 상호 에 대한 어떠한 소유권도 없습니다.
Page 95
설치 및 구성 경고 : 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토 하십시오 . 시스템 포장 풀기 랙에 레일 및 시스템 설치...
Page 97
시스템에 전원 연결 주의 : 전원 케이블이 실수로 분리되지 않도록 하려면 각 전원 공급 장치에 플 라스틱 클립을 사용하여 전원 케이블을 전원 공급 장치에 고정하고 당김 안전 끈을 사용하여 케이블을 고정 완화 막대에 고정합니다 . PDU( 주의 : 전원 케이블을 전원 콘센트에 직접 연결하지 말고 반드시 PDU 를 사용 해야...
Page 99
운영 체제 설치 완료 지원되는 운영 체제 M915 M910 M905 M805 M710 M710HD M610 M610x M605 운영 체제 Citrix XenServer 5.5 Citrix XenServer 5.6 Microsoft Windows Server 2008 Hyper-V Server Microsoft Windows Essential Business Server 2008 Standard 및 Premium Edition Microsoft Windows HPC Server 2008(x64)
Page 100
M915 M910 M905 M805 M710 M710HD M610 M610x M605 운영 체제 Microsoft Windows Server 2008 Standard, Enterprise 및 Datacenter (x64) Edition Microsoft Windows Web Server 2008 (x64) Edition Microsoft Windows Web Server 2008 (x64) Edition SP2 Microsoft Windows Server 2008 R2 Standard, Enterprise 및...
Page 101
M915 M910 M905 M805 M710 M710HD M610 M610x M605 운영 체제 Microsoft Windows Server 2003 R2 Standard 및 Enterprise(x64) Edition Microsoft Windows Server 2003 R2 Datacenter(x64) Edition Microsoft Windows Server 2003 R2 Standard, Enterprise 및 Datacenter(x64) Edition Red Hat Enterprise Linux AS, ES 및...
Page 102
M915 M910 M905 M805 M710 M710HD M610 M610x M605 운영 체제 Red Hat Enterprise Linux( 버전 5.0) (x86) Red Hat Enterprise Linux( 버전 5.0) (x86_64) Red Hat Enterprise Linux( 버전 5.2) (x86) Red Hat Enterprise 버전 5.5) Linux (x86) Red Hat Enterprise 버전...
Page 103
• 하드웨어 소유자 매뉴얼에서는 시스템 기능에 대한 정보를 제공하고 시 스템 문제 해결 방법 및 시스템 구성요소 설치 또는 교체 방법을 설명합 니다. • Dell 시스템 관리 응용프로그램 설명서에서는 시스템 관리 소프트웨어를 설치하고 사용하는 방법에 대한 정보를 제공합니다. 주: support.dell.com/manuals...
Page 104
기술 지원 얻기 하드웨어 소유자 매뉴얼 . Dell dell.com/training 기술 사양 블레이드 사양 프로세서 PowerEdge M915 AMD Opteron 6000 PowerEdge M910 Intel Xeon 7000 PowerEdge M905 AMD Opteron 8000 PowerEdge M805 AMD Opteron 2000 PowerEdge M710HD, Intel Xeon 5000 M710, M610x, M610...
Page 105
메모리 ( 계속 ) DDR3 및 DDR3L 단일, 2중 및 4중 등급 메모리 모듈, PowerEdge M710HD 정격 1066 및 1333MHz 800, 1066 또는 1333MHz DDR3 단일 또는 2중 등급 PowerEdge M710, Registered DIMM(RDIMM) 또는 Unbuffered M610x, M610, DIMM(UDIMM) 또는 800 또는 1066MHz DDR3 4중 등급 Registered DIMM(RDIMM) 또는...
Page 106
메모리 ( 계속 ) PowerEdge M710D 1GB 메모리 모듈 1개(1 프로세서 시스템) 또는 1GB PowerEdge M710, M610x, 메모리 모듈 2개(2 프로세서 시스템) M610 1GB(512MB 메모리 모듈 2개) PowerEdge M605, M600 최대 RAM PowerEdge M915 512GB PowerEdge M910 512GB PowerEdge M905 192GB PowerEdge M805 128GB...
Page 107
드라이브 ( 계속 ) PowerEdge M600, M610x, RAID, RAID RAID M610 SATA 또는 RAID RAID SATA 또는 RAID SSD(Solid-State Disk) 또는 RAID RAID PowerEdge M605 RAID RAID SATA 또는 RAID SSD(Solid State Disk) 또는 RAID RAID 주: SATA 주: RAID 커넥터...