hit counter script
Sanyo PLC-XM100/L - 5000 Lumens Manual

Sanyo PLC-XM100/L - 5000 Lumens Manual

Basic serial command functional specifications
Hide thumbs Also See for PLC-XM100/L - 5000 Lumens:
Table of Contents

Advertisement

Quick Links

BASIC SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-XM100
PLC-XM150
PLC-XM100L
PLC-XM150L
SANYO Electric Co., Ltd
DS Company
Projector Division
Ver.1.0

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-XM100/L - 5000 Lumens

  • Page 1 BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-XM100 PLC-XM150 PLC-XM100L PLC-XM150L Ver.1.0 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications Contents 1. Overview..........................5 2. Serial Interface Specification ...................5 2.1. Transfer Specification ....................5 2.2. Connection ........................5 3. Notes for Communication ....................6 4. Functional Execution Command Table................7 5. Status Read Command Table ...................9 6. Functional Execution Command ...................10 Format ........................10 When the command pipelining is needed............10 Transfer Example ....................10...
  • Page 3 PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.32 POWER MANAGEMENT CANCEL Command ............17 6.33 POWER MANAGEMENT SHUTDOWN Command ..........17 6.34 D.ZOOM + Command ....................17 6.35 D.ZOOM - Command.....................17 6.36 INPUT 3 VIDEO Command ...................17 6.37 INPUT 3 S-VIDEO Command................18 6.38 INPUT 3 Y,Pb/Cb,Pr/Cr Command ...............18 6.39 POINTER RIGHT Command .................18 6.40 POINTER LEFT Command ...................18 6.41 POINTER UP Command ..................18...
  • Page 4 PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications Setting Read Command ..................27 Temp Read Command ..................28 Lamp Mode Read Command ................28 4/28...
  • Page 5: Overview

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 1. Overview ・ These specifications define projector control commands for PLC-XM100/XM100L/XM150/XM150L ・ The projector control commands are used to control a projector through RS-232C from a computer. 2. Serial Interface Specification 2.1. Transfer Specification Item S p e c i f i c a t i o n Synchronous system...
  • Page 6: Notes For Communication

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 3. Notes for Communication ・ The projector command is defined as one command per line that starts with “C” and ends with carriage return (0x0D). ・ When carriage return (0x0D) is received, decoding starts. ・...
  • Page 7: Functional Execution Command Table

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 4. Functional Execution Command Table Command Command Item Item POWER ON BRIGHTNESS + POWER OFF (QUICK POWER BRIGHTNESS - OFF) POWER OFF INPUT 2 VIDEO INPUT 2 Y,Pb/Cb,Pr/Cr INPUT 1 INPUT 2 RGB INPUT 2 INPUT 3 IMAGE NETWORK...
  • Page 8 PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications Command Item Command Item FREEZE ON FREEZE OFF ZOOM - ZOOM + AUTO PC ADJ FOCUS - PRESENTATION TIMER FOCUS + PRESENTATION TIMER (Exit) KEYSTONE ↑ KEYSTONE ↓ INPUT 1 ANALOG RGB KEYSTONE → INPUT 1 SCART KEYSTONE ←...
  • Page 9: Status Read Command Table

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 5. Status Read Command Table Command Item Note STATUS READ INPUT MODE READ LAMP TIME READ SETTING READ TEMP READ LAMP MODE READ “ ———“ means “No Function”. 9/28...
  • Page 10: Functional Execution Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6. Functional Execution Command 6.1 Format ・ PC issues a command in the following format: “C” Command [CR] Command: two characters (See Functional Execution Command Table) ・ Projector decodes the received data and returns the result when getting ready to receive the next command.
  • Page 11: Operation Requirements

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.4 Operation Requirements 6.4.1 In the following status of projector, Available Functional Execution Commands are limited. Projector Status Available Functional Execution Commands Standby Mode C00: POWER ON C00: POWER ON → Countdown is terminated C01: POWER OFF C02: POWER OFF →...
  • Page 12: Power On Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.5 POWER ON Command Command “C00” [CR] Power ON Detail When already Power is ON, no operation is started. When sending this command during Countdown in process, Countdown is terminated. Acceptable [ACK] [CR] Response Unacceptable “?”...
  • Page 13: Input 3 Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.10 INPUT 3 Command Command “C07” [CR] Select Input 3. This command works differently from the command by “Input 3” key of the remote control. When Input 3 has been selected, this command does Detail not execute the source switching;...
  • Page 14: Volume + Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.12 VOLUME + Command Command “C09” [CR] Volume Up. Detail This command works the same way as “VOLUME +” button of the remote control. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.13 VOLUME – Command Command “C0A”...
  • Page 15: Screen Normal Size Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.18 SCREEN NORMAL SIZE Command Command “C0F” [CR] Detail Set screen size to Normal (4:3) Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.19 SCREEN WIDE SIZE Command Command “C10” [CR] Detail Set screen size to Wide (16:9) Acceptable [ACK] [CR] Response...
  • Page 16: Input 2 Video Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.25 INPUT 2 VIDEO Command Command “C23” [CR] Select Video input in Input 2. Detail Although projector returns “OK”, Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable [ACK] [CR] Response...
  • Page 17: Power Management Ready Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.31 POWER MANAGEMENT READY Command Command “C2A” [CR] Set Power Management function to ready status Detail This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Acceptable [ACK] [CR] Response Unacceptable “?”...
  • Page 18: Input 3 S-Video Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.37 INPUT 3 S-VIDEO Command Command “C34” [CR] Select S-Video input in Input 3. Detail Although projector returns “OK”, Input search is not executed with this command while Input button is set to Mode2 or Mode3. Acceptable [ACK] [CR] Response...
  • Page 19: Pointer Down Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.42 POINTER DOWN Command Command “C3D” [CR] Move down the Pointer of On-Screen Display Menu. Detail This command works differently from the command by “▼” button of the remote control and has no “Mute” Acceptable [ACK] [CR] Response...
  • Page 20: Focus + Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.48 FOCUS + Command Command “C4B” [CR] Adjust on-screen focus by making focal length longer. (The lens moves backward Detail This command works the same way as “FOCUS ▲” button of the remote control. Acceptable [ACK] [CR] Response...
  • Page 21: Lens Shift Up Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.54 LENS SHIFT UP Command Command “C5D” [CR] Detail Move projection area upward. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.55 LENS SHIFT DOWN Command Command “C5E” [CR] Detail Move projection area downward. Acceptable [ACK] [CR] Response Unacceptable...
  • Page 22: Presentation Timer (Exit) Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 6.60 PRESENTATION TIMER (Exit) Command Command “C8B” [CR] Exit P-Timer function. This command works the same way as pressing and hold Detail “P-TIMER” button of the remote control. Acceptable [ACK] [CR] Response Unacceptable “?” [CR] 6.61 KEYSTONE ↑...
  • Page 23: Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications Status Read Command 7.1 Format ・ PC issues a command in the following format. “CR” Command [CR] Command: one character (See Status Read Command Table) ・ When projector receives an appropriate command, it returns the required data in string. Required Data [CR] Required Data: string (See Status Read Command Table) ・...
  • Page 24: Status Read Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 7.4 Status Read Command Command “CR0” [CR] Detail Get the projector’s operating status Acceptable “%1” [CR] ”00” = Power ON “80” = Standby “40” = Countdown in process “20” = Cooling Down in process “10”...
  • Page 25 PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications ・ “10” [CR] Status: Power Failure When the power supply voltage inside the projector reaches abnormal status, the projector is automatically turned off. ※ Abnormal power supply voltage includes; Filter abnormal status Shutter abnormal status The projector returns “10”...
  • Page 26 PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications ・ “04” [CR] Status: Power Save This indicates it moves to Power-Save status by Power Management function as set in the Setting menu. ・ “21” [CR] Status: Cooling Down in process after OFF due to Lamp Failure When the projector is turned off due to lamp failure, it automatically starts Cooling Down operation.
  • Page 27: Input Mode Read Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 7.5 Input Mode Read Command Command “CR1” [CR] Detail Get currently selected Input No. Acceptable “%1” [CR] ”1” = Input 1 is selected. “2” = Input 2 is selected. Response “3” = Input 3 is selected. “4”...
  • Page 28: Temp Read Command

    PLC-XM100/XM100L/XM150/XM150L Basic Serial Command Functional Specifications 7.8 Temp Read Command Command “CR6” [CR] Get the information of temperature inside a projector. Detail With several built-in temperature sensors, it can get all the temperatures at once. Acceptable “%1 _ %2 _ %3” [CR] %1 = Temp.