Sign In
Upload
Manuals
Brands
Sanyo Manuals
Air Conditioner
C1872
Sanyo C1872 Manuals
Manuals and User Guides for Sanyo C1872. We have
7
Sanyo C1872 manuals available for free PDF download: Technical & Service Manual, Installation Instructions Manual, Submittal Data, Specifications
Sanyo C1872 Technical & Service Manual (131 pages)
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 9.19 MB
Table of Contents
Table of Contents
3
1 Operating Range
5
2 Specifications
6
Unit Specifications
6
SPECIFICATIONS 2-1. Unit Specifications
6
Major Component Specifications
18
Other Component Specifications
24
3 Dimensional Data
25
4 Refrigerant Flow Diagram
28
5 Performance Data
30
Temperature Charts
30
Cooling Capacity
32
6 Electrical Data
36
Electrical Characteristics
36
Electric Wiring Diagrams
38
7 Maintenance
42
Address Setting of the Remote Control Unit
42
MAINTENANCE 7-1. Address Setting of the Remote Control Unit
42
Disconnecting and Connecting Positive Connector for Outdoor Unit
43
Disassembly Procedure
44
8 Functions
51
Operation Functions
51
FUNCTIONS 8-1. Operation Functions
51
Protective Functions
53
9 Troubleshooting
54
Precautions before Performing Inspection or Repair
54
TROUBLESHOOTING 9-1. Precautions before Performing Inspection or Repair
54
Method of Self-Diagnostics
54
Operation Lamp
55
Checking the Indoor and Outdoor Units
56
Trouble Diagnosis of Fan Motor
60
Outdoor Fan Motor
61
Noise Malfunction and Electromagnetic Interference
62
10 Checking Electrical Components
63
Measurement of Insulation Resistance
63
Checking Continuity of Fuse on PCB Ass'y
64
11 Refrigerant R410A: Special Precautions When Servicing Unit
65
Characteristics of New Refrigerant R410A
65
SPECIAL PRECAUTIONS WHEN SERVICING UNIT 11-1. Characteristics of New Refrigerant R410A
65
Checklist before Servicing
66
Tools Specifically for R410A
67
Tubing Installation Procedures
67
In Case of Compressor Malfunction
68
In Case Refrigerant Is Leaking
70
Charging Additional Refrigerant
71
Retro-Fitting Existing Systems
71
Appendix Ainstruction Manual
72
Xs1271 & Pnr-Xs1872 + C1271 Xs1271 & Pnr-Xs1872 + Cl1271
72
Appendix B Installation Instructions
73
Appendix C Instruction Manual
73
Features
74
Appendix D Installation Instructions
75
Product Information
75
Alert Symbols
75
Installation Location
75
Electrical Requirements
75
Safety Instructions
75
Names of Parts
76
Using the Remote Control Unit
80
How to Install Batteries
80
Operation with the Remote Control Unit
81
Operation
81
Adjusting the Fan Speed
81
Fan Only
81
Night Setback Mode
82
HIGH POWER Mode
82
Special Remarks
82
Setting the Timer
82
Using the 1-Hour off Timer
84
Tips for Energy Saving
84
Adjusting the Airflow Direction
84
Operation Without the Remote Control Unit
85
Care and Cleaning
85
Troubleshooting
87
Operating Range
87
Wired Remote Controller
87
Installation Instructions
89
Important
90
Please Read before Starting
90
1 General
91
Tools Required for Installation (Not Supplied)
91
Accessories Supplied with Unit
91
Optional Copper Tubing Kit
91
Type of Copper Tube and Insulation Material
91
Additional Materials Required for Installation
92
2 Installation Site Selection
92
Indoor Unit
92
Outdoor Unit
93
Baffle Plate for the Outdoor Unit
94
3 How to Install the Indoor Unit
99
Preparation for Suspending
99
Suspending the Indoor Unit
99
Placing the Unit Inside the Ceiling
99
Installing the Drain Piping
100
Checking the Drainage
101
How to Install the Ceiling Panel
101
Wiring Instructions
104
Recommended Wire Length and Diameter
104
Wiring Instructions for Inter-Unit Connections
106
4 How to Install the Outdoor Unit
107
Wiring Instructions for the Outdoor Unit
107
5 Refrigerant Tubing
108
Use of the Flaring Method
108
Flaring Procedure with a Flare Tool
108
Caution before Connecting Tubes Tightly
108
Connecting Tubing between Indoor and Outdoor Units
109
Insulation of Refrigerant Tubing
109
Taping the Tubes
110
Finishing the Installation
110
6 Air Purging
110
I Air Purging with a Vacuum Pump (for Test Run)
110
I Basic Functions of the Service Valves
113
I Pump down
113
I Service Valve Connections
114
7 Remote Control Unit Installation Position
114
Mounting on a Wall
114
8 Address Switch
115
Address Setting of the Remote Control Unit
115
Remote Control Unit
119
Operation with the Remote Control Unit
122
Automatic Operation (Only for COOL/DRY/HEAT Model)
122
Manual Operation
122
Adjusting the Fan Speed
123
Fan Only
123
Night Setback Mode
123
Special Remarks
123
Setting the Timer
124
Using the 1-Hour off Timer
125
Adjusting the Airflow Direction
125
How to Install the Remote Controller
127
How to Test Run the Air Conditioner
130
Advertisement
Sanyo C1872 Technical & Service Manual (117 pages)
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 5.2 MB
Table of Contents
Table of Contents
3
1 Operating Range
5
2 Specifications
6
Unit Specifications
6
SPECIFICATIONS 2-1. Unit Specifications
6
Major Component Specifications
14
Other Component Specifications
20
3 Dimensional Data
21
4 Refrigerant Flow Diagram
24
5 Performance Data
25
Temperature Charts
25
Cooling Capacity
29
Cooling Capacity (Low Ambient)
31
Air Throw Distance Charts
33
6 Electrical Data
35
Electrical Characteristics
35
Electric Wiring Diagrams
37
7 Maintenance
41
Address Setting of the Remote Control Unit
41
MAINTENANCE 7-1. Address Setting of the Remote Control Unit
41
Disconnecting and Connecting Positive Connector for Outdoor Unit
42
8 Functions
43
Operation Functions
43
FUNCTIONS 8-1. Operation Functions
43
Night Setback
44
Protective Functions
45
9 Troubleshooting
46
Precautions before Performing Inspection or Repair
46
TROUBLESHOOTING 9-1. Precautions before Performing Inspection or Repair
46
Method of Self-Diagnostics
46
Checking the Indoor and Outdoor Units
49
Trouble Diagnosis of Fan Motor
53
Outdoor Fan Motor
54
Noise Malfunction and Electromagnetic Interference
55
10 Checking Electrical Components
56
Measurement of Insulation Resistance
56
Checking Continuity of Fuse on PCB Ass'y
57
11 Refrigerant R410A: Special Precautions When Servicing Unit
58
Characteristics of New Refrigerant R410A
58
Checklist before Servicing
59
Tools Specifically for R410A
60
Tubing Installation Procedures
60
In Case of Compressor Malfunction
61
In Case Refrigerant Is Leaking
63
Charging Additional Refrigerant
64
Retro-Fitting Existing Systems
64
Appendix Ainstruction Manual
65
Table of Contents
67
Electrical Requirements
68
Installation Location
68
Safety Instructions
68
Names of Parts
69
Unit Display and Operation Button
70
Remote Control Unit (Display)
71
Remote Control Unit
72
Using the Remote Control Unit
74
Operation with the Remote Control Unit
76
Operation
76
Adjusting the Fan Speed
77
Fan Only
77
Night Setback Mode
78
QUIET Mode
79
HIGH POWER Mode
79
ION Mode
79
Special Remarks
80
Setting the Timer
81
Tips for Energy Saving
83
Using the 1-Hour off Timer
83
Adjusting the Airflow Direction
84
Care and Cleaning
85
Operation Without the Remote Control Unit
85
Operating Range
88
Troubleshooting
88
Installation Instructions
90
Important
91
Please Read before Starting
91
1 General
92
Tools Required for Installation (Not Supplied)
92
Accessories Supplied with Unit
92
Optional Copper Tubing Kit
92
Type of Copper Tube and Insulation Material
92
Additional Materials Required for Installation
93
2 Installation Site Selection
93
Indoor Unit
93
Outdoor Unit
93
Baffle Plate for the Outdoor Unit
95
3 How to Install the Indoor Unit
98
Remove the Rear Panel from the Unit
98
Make a Hole
98
Install the Rear Panel on the Wall
99
Remove the Grille to Install the Indoor Unit
100
Shape the Indoor Side Tubing
101
Wiring Instructions
101
Recommended Wire Length and Diameter
102
Wiring Instructions for Inter-Unit Connections
103
Mounting
105
Drain Hose
106
4 How to Install the Outdoor Unit
108
Wiring Instructions for the Outdoor Unit
108
5 Refrigerant Tubing
109
Use of the Flaring Method
109
Flaring Procedure with a Flare Tool
109
Caution before Connecting Tubes Tightly
109
Connecting Tubing between Indoor and Outdoor Units
110
Insulation of Refrigerant Tubing
110
Taping the Tubes
110
Finishing the Installation
110
6 Air Purging
111
I Air Purging with a Vacuum Pump (for Test Run)
111
I Basic Functions of the Service Valves
114
I Pump down
114
7 Remote Control Unit Installation Position
115
Mounting on a Wall
115
Note
116
8 Address Switch
116
Address Setting of the Remote Control Unit
116
SANYO Commercial Solutions
117
A Division of SANYO North America Corporation
117
SANYO Canada Inc
117
Applewood Crescent, Concord Ontario, L4K 5C7, Canada
117
Sanyo C1872 Technical & Service Manual (88 pages)
DC INVERTER SPLIT SYSTEM AIR CONDITIONER
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 2.07 MB
Table of Contents
Table of Contents
3
1 Operating Range
5
2 Specifications
6
Unit Specifications
6
Major Component Specifications
14
Outdoor Unit
16
Other Component Specifications
20
3 Dimensional Data
21
4 Refrigerant Flow Diagram
24
5 Performance Data
25
Temperature Charts
25
Air Throw Distance Charts
29
6 Electrical Data
31
Electrical Characteristics
31
Electric Wiring Diagrams
33
7 Installation Instructions
37
Installation Site Selection
37
Recommended Wire Length and Diameter
39
Remote Control Unit Installation Position
40
How to Test Run the Air Conditioner
41
Remove the Grille to Install the Indoor Unit
42
8 Maintenance
43
Address Setting of the Remote Control Unit
43
Disconnecting and Connecting Positive Connector for Outdoor Unit
44
9 Functions
45
Operation Functions
45
Night Setback
46
Protective Functions
47
10 Troubleshooting
48
Precautions before Performing Inspection or Repair
48
Method of Self-Diagnostics
48
Indoor Unit
49
Checking the Indoor and Outdoor Units
51
Trouble Diagnosis of Fan Motor
52
Outdoor Fan Motor
53
Noise Malfunction and Electromagnetic Interference
54
11 Checking Electrical Components
55
Measurement of Insulation Resistance
55
Checking Continuity of Fuse on PCB Ass'y
56
12 Refrigerant R410A: Special Precautions When Servicing Unit
57
Characteristics of New Refrigerant R410A
57
Checklist before Servicing
58
Tools Specifically for R410A
59
Tubing Installation Procedures
59
In Case of Compressor Malfunction
60
In Case Refrigerant Is Leaking
62
Charging Additional Refrigerant
63
Retro-Fitting Existing Systems
63
Appendix Instruction Manual
64
Table of Contents
66
Electrical Requirements
67
Installation Location
67
Safety Instructions
67
Names of Parts
68
Unit Display and Operation Button
69
Remote Control Unit (Display)
70
Remote Control Unit
71
Using the Remote Control Unit
73
Operation with the Remote Control Unit
75
Operation
75
Adjusting the Fan Speed
76
Fan Only
76
Night Setback Mode
77
QUIET Mode
78
HIGH POWER Mode
78
ION Mode
78
Special Remarks
79
Setting the Timer
80
Tips for Energy Saving
82
Using the 1-Hour off Timer
82
Adjusting the Airflow Direction
83
Care and Cleaning
84
Operation Without the Remote Control Unit
84
Operating Range
87
Troubleshooting
87
Advertisement
Sanyo C1872 Installation Instructions Manual (28 pages)
Indoor/Outdoor Unit Inverter Split System Air Conditioner
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 2.76 MB
Table of Contents
Table of Contents
1
Installation Instructions
1
Important
2
Please Read before Starting
2
1 General
3
Tools Required for Installation (Not Supplied)
3
Accessories Supplied with Unit
3
Optional Copper Tubing Kit
3
Type of Copper Tube and Insulation Material
3
Additional Materials Required for Installation
4
2 Installation Site Selection
4
Indoor Unit
4
Outdoor Unit
5
Baffle Plate for the Outdoor Unit
6
3 How to Install the Indoor Unit
9
Remove the Rear Panel from the Unit
9
Make a Hole
9
Install the Rear Panel on the Wall
10
Remove the Grille to Install the Indoor Unit
11
Shape the Indoor Side Tubing
12
Wiring Instructions
12
Recommended Wire Length and Diameter
13
Wiring Instructions for Inter-Unit Connections
14
Mounting
16
Drain Hose
18
4 How to Install the Outdoor Unit
19
Wiring Instructions for the Outdoor Unit
19
5 Refrigerant Tubing
20
Use of the Flaring Method
20
Flaring Procedure with a Flare Tool
20
Caution before Connecting Tubes Tightly
20
Connecting Tubing between Indoor and Outdoor Units
21
Insulation of Refrigerant Tubing
21
Taping the Tubes
21
Finishing the Installation
21
6 Air Purging
22
I Air Purging with a Vacuum Pump (for Test Run)
22
I Basic Functions of the Service Valves
25
I Pump down
25
7 Remote Control Unit Installation Position
26
Mounting on a Wall
26
8 Address Switch
27
Address Setting of the Remote Control Unit
27
Sanyo C1872 Installation Instructions Manual (25 pages)
Inverter Split System Air Conditioner
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 1.29 MB
Table of Contents
Table of Contents
1
Installation Instructions
1
Important
2
Please Read before Starting
2
1 General
3
Tools Required for Installation (Not Supplied)
3
Accessories Supplied with Unit
3
Optional Copper Tubing Kit
3
Type of Copper Tube and Insulation Material
3
Additional Materials Required for Installation
4
2 Installation Site Selection
4
Indoor Unit
4
Outdoor Unit
5
Baffle Plate for the Outdoor Unit
6
3 How to Install the Indoor Unit
7
Remove the Rear Panel from the Unit
7
Make a Hole
7
Install the Rear Panel on the Wall
8
Remove the Grille to Install the Indoor Unit
9
Shape the Indoor Side Tubing
10
Wiring Instructions
10
Recommended Wire Length and Diameter
11
Wiring Instructions for Inter-Unit Connections
12
Mounting
14
Drain Hose
15
4 How to Install the Outdoor Unit
17
Wiring Instructions for the Outdoor Unit
17
5 Refrigerant Tubing
18
Use of the Flaring Method
18
Flaring Procedure with a Flare Tool
18
Caution before Connecting Tubes Tightly
18
Connecting Tubing between Indoor and Outdoor Units
19
Insulation of Refrigerant Tubing
19
Taping the Tubes
19
Finishing the Installation
19
6 Air Purging
20
Air Purging with a Vacuum Pump (for Test Run)
20
Basic Functions of the Service Valves
23
Pump down
23
7 Remote Control Unit Installation Position
24
Mounting on a Wall
24
8 Address Switch
25
Address Setting of the Remote Control Unit
25
Sanyo C1872 Specifications (2 pages)
Wall Mounted Air Conditioners & Heat Pumps 9,000-24,000 BTU/H 16-20 SEER
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 3.6 MB
Sanyo C1872 Submittal Data (2 pages)
Split System Indoor/Outdoor Wall Mounted Air Conditioner
Brand:
Sanyo
| Category:
Air Conditioner
| Size: 1.96 MB
Advertisement
Related Products
Sanyo C1852
Sanyo C1822
Sanyo C1812
Sanyo C1251
Sanyo C1211
Sanyo ECOi C1155DZH8
Sanyo ECOi C1305DXHN8
Sanyo ECOi C1305DZH8
Sanyo ECOi C1405DZH8
Sanyo ECOi C1405DXHN8
Sanyo Categories
Projector
TV
Air Conditioner
Security Camera
LCD TV
More Sanyo Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk