hit counter script
Sanyo PLC-XU116 - 4500 Lumens Manual
Sanyo PLC-XU116 - 4500 Lumens Manual

Sanyo PLC-XU116 - 4500 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XU116 - 4500 Lumens:
Table of Contents

Advertisement

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-XU116
Ver. 1.00
SANYO Electric Co., Ltd
DS Company
Projector Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-XU116 - 4500 Lumens

  • Page 1 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-XU116 Ver. 1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-XU116 Expand Serial Command Functional Specifications - CONTENTS - Overview .........................8 Serial Interface Specification ..................8 2.1 Transfer Specification ....................8 2.2 Connection .........................8 Notes for communication ....................9 Name Definition ......................9 Functional Execution Command Table ..............10 Image Command Table ..................10 PC Adjust Control Command Table ..............
  • Page 3 PLC-XU116 Expand Serial Command Functional Specifications 8.4.9 CF_PROGV Command ................. 20 8.4.10 CF_NZRED Command .................. 20 8.4.11 CF_IMAGE Command .................. 21 8.4.12 CF_IMAGEADJ Command ................21 PC Adjust Control Command ................22 8.5.1 CF_FSYNC Command .................. 22 8.5.2 CF_TDOTS Command .................. 22 8.5.3 CF_CLAMP Command..................
  • Page 4 PLC-XU116 Expand Serial Command Functional Specifications 8.8.2 CF_LAMPMODE Command ................. 35 Sound Command ....................36 8.9.1 CF_VOLUME Command ................36 8.9.2 CF_MUTE Command ..................36 8.10 Setting Command ....................37 8.10.1 CF_LANG Command ..................37 8.10.2 CF_MENUPOSITION Command ..............37 8.10.3 CF_AUTOSETUPPCADJ Command ............
  • Page 5 PLC-XU116 Expand Serial Command Functional Specifications Format ........................47 Transfer Example ....................47 Operation Condition .................... 47 Image Status Read Command ................48 9.4.1 CR_BRIGHT Command ................48 9.4.2 CR_CONT Command ..................48 9.4.3 CR_COLOR Command ................. 48 9.4.4 CR_TINT Command ..................48 9.4.5 CR_SHARP Command .................
  • Page 6 PLC-XU116 Expand Serial Command Functional Specifications Screen Status Read Command................58 9.8.1 CR_SCREEN Command ................58 9.8.2 CR_ KYSTNMODE Command ..............58 9.8.3 CR_ CORNERTESTPAT Command ............. 58 9.8.4 CR_VSCALE Command ................58 9.8.5 CR_VPOS Command ..................59 9.8.6 CR_HSCALE Command ................59 9.8.7 CR_HPOS Command ..................
  • Page 7 PLC-XU116 Expand Serial Command Functional Specifications 9.11.21 CR_PJLOCKNOW Command ..............67 9.11.22 CR_PJLOCKMENU Command ..............67 9.11.23 CR_FANMODE Command ................ 67 9.11.24 CR_FANCONTROL Command ..............67 9.11.25 CR_FILH Command .................. 68 9.11.26 CR_FILREPL Command ................68 9.11.27 CR_FILTIMER Command ................68 9.12 Other Status Read Command ................
  • Page 8: Overview

    PLC-XU116 Expand Serial Command Functional Specifications Overview 1.1 This Functional Specification defines communication functions for PLC-XU116. 1.2 Compatible to Firmware Ver. 1.x of the projector. 1.3 Most commands can be used to control projector remotely from PC by RS-232C. Therefore, the commands are defined as Expand Serial Commands.
  • Page 9: Notes For Communication

    PLC-XU116 Expand Serial Command Functional Specifications Notes for communication 1. Expand Serial Command is defined as one command / one line that starts with “C” and ends with carriage return (0x0D) 2. There are two types of commands: Functional Execution Command and Status Read Command.
  • Page 10: Functional Execution Command Table

    PLC-XU116 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Execute command Item CF_BRIGHT_%1[CR] Set Brightness value CF_CONT_%1[CR] Set Contrast value CF_COLOR_%1[CR] Set Color value CF_TINT_%1[CR] Set Tint value CF_SHARP_%1[CR] Set Sharpness value CF_GAMMA_%1[CR] Set Gamma value CF_WBAL-R_%1[CR] Set White Balance Red value CF_WBAL-G_%1[CR]...
  • Page 11: Screen Command Table

    PLC-XU116 Expand Serial Command Functional Specifications 5.4 Screen Command Table Execute command Item CF_SCREEN_%1[CR] Select Screen size CF_DZCENT_%1[CR] Cancel Digital Zoom mode CF_KEYSTONE_%1[CR] Set Keystone CF_KYSTNMODE_%1[CR] Set Keystone Store mode CF_CORNER-UL_%1[CR] Correct top-left corner CF_CORNER-UR_%1[CR] Correct top-right corner CF_CORNER-DL_%1[CR] Correct bottom-left corner CF_CORNER-DR_%1[CR] Correct bottom-right corner CF_CORNERTESTPAT_%1[CR]...
  • Page 12: Other Command Table

    PLC-XU116 Expand Serial Command Functional Specifications 5.8 Other Command Table Execute command Item Behave the same as corresponding key of CF_KEYEMU_%1[CR] projector top panel CF_MENU_%1[CR] Switch ON/OFF of each Menu. CF_POWER_%1[CR] Switch ON/OFF of Power. CF_FREEZE _%1[CR] Set Freezefunction. CF_VMUTE _%1[CR] Set No show function.
  • Page 13: Status Read Command Table

    PLC-XU116 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status read command Item CR_BRIGHT[CR] Get Brightness value CR_CONT[CR] Get Contrast value CR_COLOR[CR] Get Color value CR_TINT[CR] Get Tint value CR_SHARP[CR] Get Sharpness value CR_GAMMA[CR] Get Gamma value CR_WBAL-R[CR]...
  • Page 14: Screen Status Read Command Table

    PLC-XU116 Expand Serial Command Functional Specifications 6.5 Screen Status Read Command Table Status read command Item CR_SCREEN[CR] Get selected screen size CR_KYSTNMODE[CR] Get setting status of Keystone Store mode CR_CORNERTESTPAT[CR] Get setting status of Test pattern for Coner correction. CR_VSCALE[CR] Get setting status of Vertical Scale CR_VPOS[CR] Get setting status of Vertical Position...
  • Page 15: Other Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 6.9 Other Status Read Command Status read command Item CR_STATUS[CR] Get setting status of Projector behavior CR_SIGNAL[CR] Get Signal Status if there is a signal or not CR_VMUTE[CR] Get setting status of No Show CR_FREEZE[CR] Get setting status of Freeze CR_PTIMER[CR]...
  • Page 16: Error Code Table

    PLC-XU116 Expand Serial Command Functional Specifications 7. Error Code Table Error Code Contents -When the received data cannot be decoded -Parameter determination error (digit number error, including invalid value, etc.) The function is not available in the selected Mode Selected value is out of range (Not reflected) Command mismatched to Hardware (command for Optional function which is not installed) When reached upper or lower limit of increasing or...
  • Page 17: Functional Execution Command

    PLC-XU116 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format PC issues commands in format as below: Pattern1 : “CF_COMMAND” [CR] Pattern2 : “CF_COMMAND_”%1 [CR] CF_ : Header COMMAND : Character line %1 : Parameter (Character line) _ : Space (To separate COMMAND and Parameter) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
  • Page 18: Image Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_BRIGHT Command Command "CF_BRIGHT_%1”[CR] "000~063” --------------- Directly select Brightness setting value "UP” ----------------------- Current Brightness setting value + 1 "DN” ----------------------- Current Brightness setting value – 1 Set Brightness value of user control The value set by this command will not be saved to projector.
  • Page 19: Cf_Sharp Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command “CF_SHARP_%1”[CR] “000~015” ---------------- Directly select Sharpness setting value “UP” ------------------------ Current Sharpness setting value + 1 “DN” ------------------------ Current Sharpness setting value - 1 Set Sharpness value of user control The value set by this command will not be saved to projector.
  • Page 20: Cf_Coltemp Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1”[CR] “000” ------ Xlow “001” ------ Low “002” ------ Mid “003” ------ High Set Color Temperature. (Available only in the normal Power ON status) The value set by this command will not be saved to the projector. Therefore, when Details turning into Stanby status or ALL is OFF, the value returns to original setting.
  • Page 21: Cf_Image Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.4.11 CF_IMAGE Command Command “CF_IMAGE_%1”[CR] “DYNAMIC” ------ Dynamic (Fixed value to enable projection with a sharp, powerful picture tone) “STAND” ---------- Standard (Image adjust value is set to factory default) “REAL” ------------ Real (Fixed value to display graphic image with natural tone) “CINEMA”...
  • Page 22: Pc Adjust Control Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1”[CR] “0000~0031” --------------- Directly select Fine Sync setting value “UP” -------------------------- Current Fine Sync setting value + 1 “DN” -------------------------- Current Fine Sync setting value - 1 Set Fine Sync value of PC signal The value set by this command will not be saved to projector.
  • Page 23: Cf_H - Pos Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.5.4 CF_H – POS Command Command “CF_H-POS_%1”[CR] “0000~nnnn” --- Directly select Horizontal Position setting value “nnnn” shows maximum value, it is current Total Dots value - Display Dots value “UP” -------------- Current Horizontal Position setting value + 1 “DN”...
  • Page 24: Cf_Dline Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1”[CR] “0100”~”nnnn” --- Directly select Display Line setting value “nnnn” shows maximum value, it is current Total Line value – Vertical Position value “UP” -------------- Current Display Line setting value + 1 “DN”...
  • Page 25: Input Control Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command “CF_INPUT_%1”[CR] “CONPUTER1” ----- Select Computer1 Input “COMPUTER2” ----- Select Computer2 Input “VIDEO” --------------- Select Video Input “S-VIDEO” ------------ Select S-video “NETWORK” -------- Select Network “UP” ------------------- Switch Input setting forward Computer1 →...
  • Page 26: Cf_Input1 Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.6.3 CF_INPUT1 Command Command “CF_INPUT1_%1_”[CR] “ANALOG” ----------Select Analog RGB Input “YPBPR” ------------- Select Component “SCART” ------------- Select SCART Select Computer 1 input and source specified by %1 at the same time. Details This command is available in normal Power ON status. Acceptable “000”[CR] Response...
  • Page 27: Cf_Input_%1_%2 Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.6.8 CF_INPUT_%1_%2 Command Command “CF_INPUT_%1_%2”[CR] “COMPUTER1” ------ Select Computer1 Input “COMPUTER2” ------ Select Computer2 Input “VIDEO” ---------------- Select Analog Input “S-VIDEO” ------------- Select S-video Input When %1 is COMPUTER1 “ANALOG” ----------Select Analog RGB Input “YPBPR”...
  • Page 28: Cf_System Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.6.9 CF_SYSTEM Command Command “CF_SYSTEM_%1”[CR] “VGA1” ------------- Select VGA1 “XGA1” ------------- Select XGA1 “WXGA3” ------------ Select WXGA3 “1080I” --------------- Select 1080I Input is “1035I” --------------- Select 1035I Computer “720P” ---------------- Select 720P ”575P” ---------------- Select 575P ”480P”...
  • Page 29: Screen Control Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command “CF_SCREEN_%1”[CR] “NORMAL” ---------------------- Select Normal size “TRUE” -------------------------- Select True size “WIDE” -------------------------- Select Wide size “FULL” --------------------------- Select Full screen size “CUSTOM” ---------------------- Select Custom size Input is “DZOOM_UP”...
  • Page 30: Cf_Keystone Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command “CF_KEYSTONE_%1”[CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
  • Page 31: Cf_Corner-Ur Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.7.6 CF_CORNER-UR Command Command “CF_CORNER-UR_%1”[CR] “UP” ------------ Correct the horizontal line of image upwards “DN” ------------ Correct the horizontal line of image downwards “LEFT” --------- Correct the vertical line of image to the left “RIGHT”...
  • Page 32: Cf_Cornertestpat Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.7.9 CF_CORNERTESTPAT Command Command “CF_CORNERTESTPAT_%1”[CR] “RED” ------------Select Red “WHITE” -------- Select White “BLUE” ---------- Select Blue “OFF” ------------ Select Off Display test patterns for Correctcorrection. (Available in normal Power ON status only) Details The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF.
  • Page 33: Cf_Vpos Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.7.11 CF_VPOS Command Command “CF_VPOS_%1”[CR] “015” --------- +15 “014” --------- +14 ÿ “002” --------- +2 “001” --------- +1 “000” --------- +0 “-01” ---------- -1 “-02” ---------- -2 ÿ “-14” ---------- -14 “-15” ---------- -15 “UP”...
  • Page 34: Cf_Hpos Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.7.13 CF_HPOS Command Command “CF_HPOS_%1”[CR] “015” --------- +15 “014” --------- +14 ÿ “002” --------- +2 “001” --------- +1 “000” --------- +0 “-01” ---------- -1 “-02” ---------- -2 ÿ “-14” ---------- -14 “-15” ---------- -15 “UP”...
  • Page 35: Lamp Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPH Command Command “CF_LAMPH_%1”[CR] “RST” Details Reset Lamp use time counter. (Available in normal Power ON status only). Acceptable “000”[CR] Response Unacceptable “Error Code”[CR] 8.8.2 CF_LAMPMODE Command Command “CF_LAMPMODE_%1”[CR] “HIGH” ------------ Set lamp to High mode “NORMAL”...
  • Page 36: Sound Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1”[CR] “000-063” -------------------------- Directly select Volume setting value “UP” --------------------------------- Current Volume setting value +1 “DN” --------------------------------- Current Volume setting value -1 Control Volume value The same operation of Volume Up/Down as projector and RC, and directly select Volume setting value.
  • Page 37: Setting Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_LANG Command Command “CF_LANG_%1”[CR] “ENG” --------------------------- Select English “DEU” --------------------------- Select German “FRA” --------------------------- Select French “ITA” ----------------------------- Select Italian “ESP” ---------------------------- Select Spanish “POR” --------------------------- Select Portuguese “NED” --------------------------- Select Dutch “SVE”...
  • Page 38: Cf_Autosetupkeystone Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.10.4 CF_AUTOSETUPKEYSTONE Command Command “CF_AUTOSETUPKEYSTONE_%1”[CR] “AUTO” ------------------- Set Auto Keystone function to Auto “MANUAL” --------------- Set Auto Keystone function to Manual “OFF” --------------------- Set Auto Keystone function to OFF Set Keystone function of Auto setup This command is available in normal Power ON status.
  • Page 39: Cf_Disp Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.10.8 CF_DISP Command Command “CF_DISP_%1”[CR] “ON” ----------------------------- Select Display “OFF” --------------------------- Cancel Display “CNTDWNOFF” -------------- Count down OFF “UP” --------------- Switch Display mode forward (On → Count down OFF → Off → On → 0û 0 û ) “DN”...
  • Page 40: Cf_Usbterminal Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.10.10 CF_USBTERMINAL Command Command “CF_USBTERMINAL_%1”[CR] “DISPLAY” ------------------Select Display “MOUSE” ------------------- Select Mouse control Switch usage of USB terminal. The value set by this command is stored in EEPROM and its setting is effective Details even after ALL is OFF This command is available in normal Power ON status.
  • Page 41: Cf_P-Mane Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.10.14 CF_P-MANE Command Command “CF_Pÿ MANE_%1”[CR] “OFF” --------------------------------- Set Power Management to OFF “READY” ----------------------------- Set Power Management to Ready “SHUTDOWN” --------------------- Set Power Management to Shut Down mode “UP” ------------------------------ Switch Power management setting (Off →...
  • Page 42: Cf_Ccaptiondisp Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.10.18 CF_CCAPTIONDISP Command Command “CF_CCAPTIONDISP_%1”[CR] “OFF” ------------- Select Off “CC1” ------------- Select CC1 “CC2” ------------- Select CC2 “CC3” ------------- Select CC3 “CC4” ------------- Select CC4 Select channel of Closed caption. The status set with this command is stored in EEPROM and its setting is effective even after ALL is OFF.
  • Page 43: Cf_Keydis Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.10.21 CF_KEYDIS Command Command “CF_KEYDIS_%1”[CR] “NONE” ----------------------- RC & Projector keys are valid (All are valid) “RC” ---------------------------- RC keys are invalid “KEY” -------------------------- Projector keys are invalid Diable RC/Projector keys Details This command is available in normal Power ON status. Acceptable “000”[CR] Response...
  • Page 44: Cf_Fancontrol Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.10.24 CF_FANCONTROL Command Command “CF_FANCONTROL_%1”[CR] “OFF” ---------------------------- Set Fan control to Off “ON1” ---------------------------- Set Fan control to On1 “ON2” ---------------------------- Set Fan control to On2 “ON3” ---------------------------- Set Fan control to On3 Set Fan control setting. The status set by this command is stored in EEPROM and its setting is effective Details even after ALL is OFF.
  • Page 45: Other Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.11 Other Command 8.11.1 CF_KEYENU Command Command “CF_KEYENU_%1”[CR] “RIGHT” ------------------------- Shift Pointer on OSD Menu to right “LEFT” --------------------------- Shift Pointer on OSD Menu to left “UP” ------------------------------ Shift Pointer on OSD Menu to right “DN”...
  • Page 46: Cf_Freeze Command

    PLC-XU116 Expand Serial Command Functional Specifications 8.11.4 CF_FREEZE Command Command “CF_FREEZE_%1”[CR] “ON” ------------------------ Set Freeze to ON “OFF” ----------------------- Set Freeze to OFF “UP” ------------------------------ Switch setting (On → Off → On → ÿ e ÿ e ÿ e ) “DN”...
  • Page 47: Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format PC issues commands in format as below: “CR_Command” [CR] Command : Character Line When projector receives the appropriate command, it returns a character line as the required data “000ÿ...
  • Page 48: Image Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.4 Image Status Read Command 9.4.1 CR_BRIGHT Command Command “CR_BRIGHT”[CR] Details Get Brightness value of user control Acceptable “000_ÿ ÿ A ”[CR] Response “000”~“063” Unacceptable “Error Code”[CR] 9.4.2 CR_CONT Command Command “CR_CONT”[CR] Details Get Contrast value of user control Acceptable “000_ÿ...
  • Page 49: Cr_Gamma Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.4.6 CR_GAMMA Command Command "CR_GAMMA”[CR] Details Get Gamma value of user control Acceptable “000_%a”[CR] Response “000”~“015” Unacceptable “Error Code”[CR] 9.4.7 CR_WBAL – R Command Command "CR_WBAL-R”[CR] Details Get White Balance Red value of user control Acceptable “000_%a”[CR] Response...
  • Page 50: Cr_Nzred Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.4.11 CR_NZRED Command Command “CR_NZRED”[CR] Details Get setting status of Noise Reduction Acceptable “000_%1”[CR] “L1” -------- Noise Reduction for moving image Response “L2” -------- Noise Reduction for still image “OFF” ----- Noise Reduction is OFF Unacceptable “Error Code”[CR] 9.4.12 CR_PROGV Command...
  • Page 51: Pc Adjust Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC”[CR] Details Get Fine Sync value Acceptable “000_%a”[CR] “0000”~“0031” Response “Error Code”[CR] ----- When the command is invalid due to Unacceptable condition such as Input source “?”[CR] -------------------- When unclear command is received 9.5.2 CR_TDOTS Command...
  • Page 52: Cr_V - Pos Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.5.5 CR_V – POS Command Command “CR_V POS”[CR] Details Get Vertical Position value Acceptable “000_%a”[CR] “0000”~“nnnn” (nnnn = Total Line - Display Line) Response “Error Code”[CR] -------- When the command is invalid due to Unacceptable condition such as Input source “?”[CR] ----------------------- When unclear command is received...
  • Page 53: Video Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS”[CR] Get currently selected signal Details Returns auto-detected signal in Auto mode Only available for Video input. (N/A when Input is computer) Acceptable “000_%a”[CR] “1080I60” -------------- 1080i 60Hz “1080I50”...
  • Page 54: Input Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.7 Input Status Read Command 9.7.1 CR_INPUT Command Command “CR_INPUT”[CR] Details Get selected INPUT No. Acceptable “000_%1”[CR] Response Request data “1”-”5” Unacceptable “Error Code”[CR] 9.7.2 CR_SOURCE Command Command “CR_SOURCE”[CR] Details Get selected Source Acceptable “000_%1”[CR] “DIGITAL”...
  • Page 55: Cr_Srcinp4 Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.7.6 CR_SRCINP4 Command Command "CR_SRCINP4” [CR] Details Get selected source of Input 4_S-video Acceptable “000_%1”[CR] Response Request data “Sÿ VIDEO” -------- S-Video Input is selected Unacceptable “Error Code”[CR] 9.7.7 CR_SRCINP5 Command Command "CR_SRCINP5” [CR] Details Get selected source of Input 5_Network Acceptable...
  • Page 56: Cr_System Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.7.8 CR_SYSTEM Command Command “CR_SYSTEM”[CR] Details Get selected System Acceptable “000_%1”[CR] “VGA1” -------------- VGA1 is selected “VGA2” -------------- VGA2 is selected ÿ “XGA1”-------------- XGA1 is selected ÿ “WXGA3” --------- WXGA3 is selected “1080i” ------------ 1080i is selected “1035i”...
  • Page 57: Cr_Syslist Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.7.9 CR_SYSLIST Command Command “CR_SYSLIST”[CR] Details Get selectable System titles Acceptable “000_%1_%2_..._%x” [CR] - When Input is PC-Analog “XGA1” ------------ XGA1is selectable “1080I ” ----------- 1080i is selectable Projector does not return Auto,Mode1-5 When there is no signal, it returns Error Code “101” -When Input is PC-Digitalÿ...
  • Page 58: Screen Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.8 Screen Status Read Command 9.8.1 CR_SCREEN Command Command “CR_SCREEN”[CR] Details Get selected on-screen image size Acceptable “000_%a”[CR] “NORMAL” --------------- Normal mode is selected “TRUE” -------------------- True mode is selected Input “WIDE” --------------------- Wide mode is selected “FULL”...
  • Page 59: Cr_Vpos Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.8.5 CR_VPOS Command Command “CR_VPOS”[CR] Details Get setting status of Vertical Position Store Mode Acceptable “000_%1”[CR] Response “-15” ~ “015” Unacceptable “Error Code”[CR] 9.8.6 CR_HSCALE Command Command “CR_HSCALE”[CR] Details Get setting status of Horizontal Scale Store Mode Acceptable “000_%1”[CR] Response...
  • Page 60: Lamp Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL”[CR] Details Get information of Lamp Replacement time Acceptable “000_%1”[CR] “1Y” -------------------------- Over lamp replacement time “1N” -------------------------- Within lamp replacement time “1” means the number of lamps. Response (1 lamp model→...
  • Page 61: Cr_Lampmsts Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.9.5 CR_LAMPMSTS Command Command “CR_LAMPSTS”[CR] Details Get Lighting status of lamp Acceptable “000_%1”[CR] “ÿ N **** ” A number of * should be among 1-4. First character shows how many lamps are incorporated in projector.
  • Page 62: Sound Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME”[CR] Details Get Volume value of user control Acceptable “000_%a”[CR] Response “000”~“063” Unacceptable “Error Code” [CR] 9.10.2 CR_MUTE Command Command “CR_MUTE”[CR] Details Get sound mute setting status Acceptable “000_%a”[CR] “ON”...
  • Page 63: Setting Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG”[CR] Details Get selected language Acceptable “000_%a”[CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
  • Page 64: Cr_Backgnd Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.11.5 CR_BACKGND Command Command “CR_BACKGND” [CR] Details Get setting status of Screen for no signal Acceptable “000_%1” [CR] “BLUE” -------------------------------- Blue Back is selected Response “USER” ------------------------------- User is selected “BLACK” ------------------------------ Black Back is selected Unacceptable “Error Code”...
  • Page 65: Cr_Rear Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.11.10 CR_REAR Command Command “CR_REAR” [CR] Details Get setting status of Rear Acceptable “000_%1”[CR] “ON” ------------------------------ Rear is ON Response “OFF” ----------------------------- Rear is OFF Unacceptable “Error Code” [CR] 9.11.11 CR_POINTER Command Command “CR_POINTER” [CR] Details Get Pointer setting status Acceptable...
  • Page 66: Cr_Standbymode Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.11.15 CR_STANDBYMODE Command Command “CR_STANDBYMODE” [CR] Details Get Standby Mode setting status Acceptable “000_%a”[CR] “ECO” -------------- Eco Mode Response “NORMAL” -------- Normal Mode(Network is selected) Unacceptable “?”[CR] 9.11.16 CR_CCAPTIONDISP Command Command “CR_CCAPTIONDISP”[CR] Details Get selected channel of Closed caption Acceptable “000_%a”[CR] “OFF”...
  • Page 67: Cr_Keydis Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.11.20 CR_KEYDIS Command Command “CR_KEYDIS”(CR) Details Get disablility status of RC/Projector keys (valid or invalid) Acceptable “000_%a”[CR] “NONE” -------------------------- RC / Projector keys are valid Response “RC” ------------------------------ RC keys are invalid “KEY” ----------------------------- Projector keys are invalid Unacceptable “Error Code”...
  • Page 68: Cr_Filh Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.11.25 CR_FILH Command Command “CR_FILH”[CR] Details Get Filter used time Acceptable “000_%1”[CR] Response “00000”~”99999” ------------------- 0 hour to 99999 hours Unacceptable “Error Code”[CR] 9.11.26 CR_FILREPL Command Command “CR_FILREPL”[CR] Details Get the information of Filter replacement time Acceptable “000_%1”[CR] “1Y”...
  • Page 69: Other Status Read Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.12 Other Status Read Command 9.12.1 CR_STATUS Command Command “CR_STATUS”(CR) Get status of Projector behavior. Details This command affects the same as ”CR0” of Basic Serial command, but this has an error code. Acceptable “000_%1”[CR] “00”= Power ON “80”= Stand by...
  • Page 70: Cr_Ptimer Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.12.5 CR_PTIMER Command Command "CR_PTIMER”[CR] Details Get status of Presentation Timer Acceptable “000_%a”[CR] “ON” -------------------- Presentation timer is in operation Response “STOP” ----------------- Presentation timer is paused “OFF” ------------------- Presentation timer is not operating Unacceptable “Error Code”...
  • Page 71: Cr_Temp Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.12.7 CR_TEMP Command Command "CR_TEMP”[CR] Get current temperature inside a projector. Details If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable “000_%1_%2_%3”[CR] %1= Sensor 1 temperature (Outside temperature) %2= Sensor 2 temperature (Inside temperature1) %3= Sensor 3 temperature (Inside temperature2) %1,%2 are consists of 6 bites fixed...
  • Page 72: Cr_Tempfail Command

    PLC-XU116 Expand Serial Command Functional Specifications 9.12.8 CR_TEMPFAIL Command Command "CR_TEMPFAIL”[CR] Get the temperature inside a projector when abnormal temperature occurs. Details If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable “000_%a_%b_%c”[CR] %a ------------------ Sensor 1 temp.

This manual is also suitable for:

Plc-xu116

Table of Contents