Use Dell Storage Manager to edit the Storage Center settings and set the operation mode of the Storage Center to Maintenance
mode.
Steps
1.
Remove the front bezel from the storage system.
2.
Locate the failed hard drive in the storage system.
3.
Press the release button to open the hard drive carrier release handle.
4.
Slide the hard drive carrier out of the hard drive slot.
Install the Replacement Drive
Use this procedure to install a drive in the SCv3000 and SCv3020 storage system.
Steps
1.
Open the release handle on the drive carrier and insert the hard drive carrier into the open drive slot.
2.
Slide the drive into the slot until the drive carrier contacts the midplane.
3.
Close the drive carrier handle to lock the drive in place.
4.
Continue to push firmly until you hear a click and the drive carrier handle fully engages.
5.
Clear the drive swap status from the Hardware tab in Dell Storage Manager.
For instructions, see the Storage Manager Administrator's Guide.
Next steps
1.
Install the front bezel on the storage system.
2.
Use Dell Storage Manager to edit the Storage Center settings and set the operation mode of the Storage Center to Normal
mode.
3.
Use Dell Storage Manager to send SupportAssist information to Dell Technical Support.
Rack Rails
Rack rails are used to install the storage controller into a rack.
Remove the Rack Rails
Prerequisites
1.
Use SupportAssist to send diagnostic data to Dell Technical Support.
2.
Shut down the storage system using the Dell Storage Manager.
About this task
NOTE: Replacing rack rails must be performed during a scheduled maintenance window when the Storage Center system
is unavailable to the network.
Steps
1.
Make sure all the cables are labeled.
2.
Disconnect all of the cables from the storage system.
3.
Loosen the screws in the chassis ears that secure the chassis to the rack.
Replacing SCv3000 and SCv3020 Storage System Components
15